I believe that when you are riding DAYLYRIDE Bike, you have more or less encountered the situation that the e-bike has problems and needs to reset parameters. Today, let’s teach our riders some related parameter settings and the parameters represented by the codes.
Error code (error code starting with E)
Error Code | Problem Parts |
E00 | Normal |
E02 | Brakes |
E06 | Battery undervoltage |
E07 | Motor failure |
E08 | Turn malfunctioning |
E09 | Controller failure |
E10 | Communication reception failure |
E11 | Communication dispatch failure |
Regarding error codes, we often receive feedback from customers that E10.
There is a corresponding solution for this error code:
If E10 is present, you need to disconnect the cable connectors of all parts individually to check whether the E10 disappears.
To determine which part can cause E10 to disappear when its cable interface is disconnected. You can try to disconnect the cables of the ebike parts individually, and check if the E10 disappears after disconnecting the cable of one of the parts, if the E10 disappears, it means that the corresponding part of the disconnected cable is faulty. ( Please note that only disconnect the cable of one component at a time, and then check whether E10 disappears. If E10 still exists, reconnect the cable, continue to disconnect the cable of another component, and continue to troubleshoot.)
Default Parameter Codes
Restore default setting method:
① Start the power, press the + & - button at the same time, then press the power button to enter P01-P20, and press the + / - button to adjust the number of the setting.
② P1 to P20 are adjusted to the corresponding numbers, after each adjustment, press the + & - button at the same time to save.
DAYLYRIDE Ebike P01 - P20 Default Parameter Settings
Adjust Code | Adjustment Parts | Adjust Value Celection |
P01 |
Backlight brightness |
001/002/003 |
P02 |
Mileage unit | 000/001 |
P03 | Voltage level | 048 |
P04 | Dormancy time | 010 |
P05 | PAS number selection | 001 |
P06 | Wheel setting | 20/26/27.5 |
P07 | Speed gauge magnetic steel number | 001 |
P08 | Speed limit setting | 100 |
P09 | zero start, non-zero start setting | 000 |
P10 | Riding mode | 002 |
P11 | Help sensitivity setting | 003 |
P12 | Help start intensity setting | 003 |
P13 | Power Magnetic Steel Disk Type Setting | 012 |
P14 | Controller limit value setting | 015 |
P15 | Controller undervoltage | 39 |
P16 | ODO zero setting | 000 |
P17 | Automatic cruise optional | 000 |
P18 | Display speed ratio adjustment | 100 |
P19 | Zero PAS selection | 000 |
P20 | 0:2 Protocol 1:5 S Protocol 2: Standby 3: Standby | 000 |
If you still don't understand how to set it up, click here to learn more.
Conclusion
If you have any questions, you can solve them according to the above methods. If there is really no way to solve them, you can contact us through the website or email. We offer a two-year warranty on every order, if you have any questions, please don't be shy to contact us and we will answer you as soon as possible.